Abstract

Aim: An immunomagnetic capture protocol for use with LC–MS was developed for the quantitation of saxitoxin (STX) in human urine. Materials & methods: This method uses monoclonal antibodies coupled to magnetic beads. STX was certified reference material grade from National Research Council, Canada. Analysis was carried out using LC–MS. Results: With an extraction efficiency of 80%, accuracy and precision of 93.0–100.2% and 5.3–12.6%, respectively, and a dynamic range of 1.00–100 ng/ml, the method is well suited to quantify STX exposures based on previously reported cases. Conclusion: Compared with our previously published protocols, this method has improved selectivity, a fivefold increase in sensitivity and uses only a third of the sample volume. This method can diagnose future toxin exposures and may complement the shellfish monitoring programs worldwide.

Graphical abstract

Keywords:

  • antibody
  • immunocapture
  • liquid chromatography
  • magnetic beads
  • marine toxins
  • MS
  • saxitoxin