Search
Close this search box.

Abstract

Aim: Ivosidenib is a potent and selective small molecule inhibitor of mutant isocitrate dehydrogenase 1. Accurate measurement of ivosidenib is the key to ivosidenib pharmacokinetics in clinical trials. Materials & methods: Quantitation of ivosidenib was conducted by using a stable isotope labeled compound (ivosidenib-d4) as the internal standard. Results: This assay was validated and successfully applied to support multiple clinical trials. Selected clinical samples were also tested by a chiral LC–MS/MS method against four ivosidenib isomer standards to exclude the possibility of in vivo racemization of ivosidenib. Conclusion: A robust LC–MS/MS method was validated for ivosidenib in human plasma. This is the first time for ivosidenib bioanalytical method in any human matrix to be reported.

Keywords:

  • acute myeloid leukemia
  • AML
  • chiral separation
  • human plasma
  • IDH inhibitor
  • ivosidenib
  • LC–MS/MS
  • oncology
  • small molecule
  • validation