Aim: We aimed to establish and validate a simple and sensitive UPLC–MS/MS method for the determination of UNC1999, a dual inhibitor against EZH1 and EZH2 in plasma samples. Materials & methods: UNC1999 in rat plasma was processed with protein precipitation method and then separated on a C18 column and detected under positive ionization mode. The method presented good linearity over the range of 1.0–2000 ng/ml with good accuracy and precision. UNC1999 was absorbed slowly and achieved a maximum concentration of 118.8 ± 12.0 ng/ml 1.5 h after oral administration. Conclusion: The method provides a favorable character in selectivity, linearity, accuracy, precision, recovery, matrix effects and stabilities and was suitable for describing the pharmacokinetic profile of UNC1999.